We have prepared files for designers with our profiles. Now interior visualization using aluminum products is even easier
cad file
installation guide
installation guide
installation
Fasten to the ceiling using self-tapping screws or anchors through mounting angle brackets; fixing spacing not exceeding 1 m on straight sections and 0.7 m on curved sections.
Without transitions or gaps. Using a Ø3 mm rod and a 15 mm wide band.
If there are straight internal corners, the membrane cut is adjusted accordingly.
The upper-level membrane is inserted using a standard straight spatula, while the lower-level membrane is inserted using a spatula with a working edge at least 35 mm long and angled at 70–90°.